Término solicitado: BAJO VOLTAJE/(265,65,175)
4 Registro/s encontrado/s en CAT+NORMA
Tipo de documento:
|
NORMA |
Título:
|
COMPATIBILIDAD ELECTROMAGNETICA (CEM). PARTE 3 - LIMITES. SECCION 3 - LIMITACION DE LAS VARIACIONES DE TENSION, FLUCTUACIONES DE TENSION Y DEL PARPADEO ("FLICKER") EN REDES PUBLICAS DE SUMINISTRO DE BAJA TENSION PARA LOS EQUIPOS CON CORRIENTE DE ENTRADA |
Código de Doc.:
|
IRAM 2491-3-3:2009 |
Autor Inst.:
|
Instituto Argentino de Normalización y Certificación. IRAM |
Fecha:
|
2009 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
Argentina |
ICS:
|
33.100.10 Emisión |
Idioma:
|
es |
Título en otro Idioma:
|
Electromagnetic compatibility (EMC). Part 3 - Limits. Section 3 - Limitation of voltage changes, voltage fluctuation and flicker in public low-voltage supply systems,for equipment with rated current 16 A per phase and not subject to conditional connect |
Edición:
|
Segunda edición |
Notas:
|
IRAM 2491-3-3:2009 IEC 61000-3-3:1994. Reemplaza a IRAM 2491: 1999 |
Palabras Clave: |
Compatibilidad electromagnética;
Corriente eléctrica;
Límites;
Voltaje;
Variaciones;
Red pública;
Bajo voltaje;
Equipos eléctricos
|
Páginas:
|
28p. |
Ingreso de la Info.:
|
2016-11-25 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION |
Código de Doc.:
|
IEC 60364-6 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2006 |
Estado: |
|
Campo de Aplic.:
|
Provides requirements for initial verification, by inspection and testing, of an electrical installation to determine, as far as reasonably practicable, whether the requirements of the other parts of IEC 60364 have been met and requirements for the reporting of the results of the initial verification. The initial verification takes place upon completion of a new installation or completion of additions or of alterations to existing installations. Provides requirements for periodic verification of an electrical installation to determine, as far as reasonably practicable, whether the installation and all its constituent equipment are in a satisfactory condition for use and requirements for the reporting of the results of the periodic verification |
ICS:
|
91.140.50 Electricity supply systems |
Idioma:
|
fr;en |
Título en otro Idioma:
|
Installations électriques à basse tension - Partie 6: Vérification |
Edición:
|
1.0 edition |
Palabras Clave: |
Edificios;
Instalaciones eléctricas;
Seguridad eléctrica;
Bajo voltaje;
Verificación;
Inspección;
Resistencia eléctrica;
Aislamiento;
Impedancia
|
Páginas:
|
42p. |
Ingreso de la Info.:
|
2012-02-01 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT = 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION |
Código de Doc.:
|
IEC 61000-3-3 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2005 |
Estado: |
|
Objeto:
|
This section of IEC 61000-3 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. This section is applicable to electrical and electronic equipment having an input current up to and including 16 A per phase and intended to be connected to public low-voltage distribution systems of between 220 V and 250 V at 50 Hz line to neutral. This publication supersedes IEC 60555-3. This consolidated version consists of the first edition (1994), its amendment 1 (2001) and its amendment 2 (2005). Therefore, no need to order amendments in addition to this publication |
Relac. con otras Normas:
|
IEC 60050; IEC 60050-161; IEC 60065; IEC 60107-1; IEC 60155 |
ICS:
|
33.100.10 Emission |
Idioma:
|
fr;en |
Título en otro Idioma:
|
Compatibilité électromagnetiqué (CEM) - Partie 3-3: Limites - Limitations des variations de tension, des fluctuations de tension et du papillotement dans les réseaux publics d'alimentation base tension pour les materiels ayant un assigne 16 |
Edición:
|
1.2 edition |
Palabras Clave: |
Compatibilidad electromagnética;
Corriente eléctrica;
Límites;
Voltaje;
Variaciones;
Red pública;
Bajo voltaje;
Equipos eléctricos
|
Páginas:
|
53p. |
Ingreso de la Info.:
|
2010-12-02 |
Tipo de documento:
|
NORMA |
Título:
|
HIGH-CURRENT TEST TECHNIQUES - DEFINITIONS AND REQUIREMENTS FOR TEST CURRENTS AND MEASURING SYSTEMS |
Código de Doc.:
|
IEC 62475 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2010 |
Estado: |
|
Objeto:
|
IEC 62475:2010 is applicable to high-current testing and measurements on both high-voltage and low-voltage equipment. It deals with steady-state and short-time direct current (as e.g. encountered in high-power d.c. testing), steady-state and short-time alternating current (as e.g. encountered in high-power a.c. testing), and impulse-current. In general, currents above 100 A are considered in this International Standard, although currents less than this can occur in tests. This standard also covers fault detection during, for example, lightning impulse testing
|
Relac. con otras Normas:
|
IEC 60051-2; IEC 60060-1; IEC 61180-1; ISO/IEC Guide 98-3 |
ICS:
|
19.080 Electrical and electronic testing |
Idioma:
|
en; fr |
Título en otro Idioma:
|
Techniques des essais à haute intensité - Définitions et exigences relatives aux courants d'essai et systèmes de mesure
|
Edición:
|
1.0 edition |
Palabras Clave: |
Energía eléctrica;
Equipos de ensayo;
Mediciones eléctricas;
Alto voltaje;
Bajo voltaje;
Corriente eléctrica;
Corriente continua;
Equilibrio;
Cargas eléctricas
|
Páginas:
|
216p. |
Ingreso de la Info.:
|
2010-11-30 |
Fin
[Página de Inicio]