Tipo de documento:
|
NORMA |
Título:
|
EFFECT OF INSTRUMENTAL BANDPASS FUNCTION AND MEASUREMENT INTERVAL ON SPECTRAL QUANTITIES |
Código de Doc.:
|
CIE 214:2014 |
Autor Inst.:
|
Commission Internationale de L'Eclairage. CIE |
Fecha:
|
2014 |
Estado: |
|
País de Origen:
|
Austria |
Objeto:
|
This report presents a detailed study of bandwidth correction applied to spectra encountered in radiometric, photometric and spectrophotometric measurements. The mechanism of broadening of data recorded by both scanning and array spectrometers, due to bandpass function effects, is discussed in detail, along with an historical study of methods currently applied. The report presents a bandwidth correction algorithm that can be used for any real bandpass function and provides both a step-by-step guide on how to apply that correction, and a discussion of the theoretical and experimental limits to its applicability.The effect of noise and measurement interval in measurement of both the spectrum and the bandpass function is discussed and methods for identifying the significance of noise effects in the corrected spectrum are presented. The reduced effect of noise when calculating spectrally integrated quantities (such as photometric or colorimetric values) is also examined. Practical guidelines are given for the application of bandwidth correction, both for the determination of the bandpass function and for estimating whether the correction may lead to an improvement in spectral accuracy. |
Otros Códigos:
|
ISBN: 978-3-902842-53-4 |
Idioma:
|
en |
Palabras Clave: |
Guia;
Instrumentos de medicion;
Aparatos de medicion;
Instrumentos musicales;
Analisis espectral;
Espectrofotometros;
Fotometria;
Radiometria
|
Páginas:
|
86p. |
Ingreso de la Info.:
|
2019-08-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-1: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. APARATOS DE MEDIDA |
Código de Doc.:
|
UNE-EN 55016-1-1:2008/A2:2009 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2009 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Relac. con otras Normas:
|
CISPR 16-1-1:2006/A2:2007 |
ICS:
|
17.220.20 Medición de magnitudes eléctricas y magnéticas; 33.100 Compatibilidad electromagnética (CEM) |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Appareils de mesure |
Edición:
|
primera edición |
Notas:
|
Esta norma es la versión oficial, en español, de la norma EN 55016-1-1:2007/A2:2008. Debe ser leida junto con UNE-EN 55016-1-1:2008 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Mediciones;
Perturbaciones radioeléctricas;
Receptores;
Inmunidad;
Equipos;
Compatibilidad electromagnética
|
Páginas:
|
12p. |
Ingreso de la Info.:
|
2010-02-02 |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-4: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. EQUIPO(S) AUXILIAR(ES). PERTURBACIONES RADIADAS |
Código de Doc.:
|
UNE-EN 55016-1-4:2008/A1:2009 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2009 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Relac. con otras Normas:
|
CISPR 16-1-4:2007/A1:2007 |
ICS:
|
17.220.20 Medición de magnitudes eléctricas y magnéticas; 33.100 Compatibilidad electromagnética (CEM) |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-4: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-4: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Perturbations rayonnées |
Edición:
|
primera edición |
Notas:
|
Esta norma es la versión oficial, en español, de la norma EN 55016-1-4:2007/A1:2008. Debe ser leida junto con UNE-EN 55016-1-4:2008 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Mediciones;
Pinza absorbente;
Perturbaciones radioeléctricas;
Perturbaciones radiadas;
Inmunidad;
Equipos;
Validación;
Compatibilidad electromagnética
|
Páginas:
|
26p. |
Ingreso de la Info.:
|
2010-02-02 |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS PARTE 1-2: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS EQUIPO(S) AUXILIAR(ES) PERTURBACIONES CONDUCIDAS (CISPR 16-1-2:2003) |
Código de Doc.:
|
UNE-EN 55016-1-2:2007/A2:2008 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-2: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Perturbations conduites |
Edición:
|
primera |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Perturbaciones conducidas;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
16p. |
Ingreso de la Info.:
|
2009-02-24 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-4: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. EQUIPO(S) AUXILIAR(ES). PERTURBACIONES RADIADAS |
Código de Doc.:
|
UNE-EN 55016-1-4 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica las caracteristícas y funcionamiento de los equipos de medida de perturbaciones radiadas en el rango de frecuencia de 9 KHz a 18 GHz |
Campo de Aplic.:
|
Se incluye especificaciones para equipos auxiliares tales como; antenas y emplazamientos de ensayo, celdas TEM y cámaras reverberantes |
Relac. con otras Normas:
|
CISPR 16-1-1; CISPR 16-2-3; CISPR 16-3; CISPR 16-4; IEC 60050-161 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-4: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-4: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Perturbations rayonnées |
Edición:
|
primera |
Notas:
|
Esta es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-4:2004:2007, que a su vez adopta la norma internacional CISPR 16-1-4:2007 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Pertubaciones radiadas;
Inmunidad;
Validación;
Compatibilidad electromagnética
|
Páginas:
|
94p. |
Ingreso de la Info.:
|
2009-02-18 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-2: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. MEDIDA DE LA POTENCIA PERTURBADORA. (CISPR 16-2-2:2003/A1:2004) |
Código de Doc.:
|
UNE-EN 55016-2-2:2007/A1:2008 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power (CISPR 16-2-2:2003/A1:2004); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-2: Méthodes de mesure des perturbations et de l'immunité - Mesure de la puissance perturbatrice (CISPR 16-2-2:2003/A1:2004) |
Edición:
|
primera |
Notas:
|
Esta primera modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-2:2004/A1:2005, que a su vez adopta las normas internacionales CISPR 16-2-2:2003/A1:2004 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Potencia perturbadora;
Inmudidad;
Compatibilidad electromagnética;
Pinza de absorción
|
Páginas:
|
16p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-1: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. MEDIDAS DE LAS PERTURBACIONES CONDUCIDAS. (CISPR 16-2-1:2003/A1:2005) |
Código de Doc.:
|
UNE-EN 55016-2-1:2007/A1 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
E |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements (CISPR 16-2-1:2003/A1:2005); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-1: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations conduites (CISPR 16-2-1:2003/A1:2005) |
Edición:
|
primera |
Notas:
|
Esta primera modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-1:2004/A1:2005, que a su vez adopta las normas internacionales CISPR 16-2-1:2003/A1:2005 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Perturbaciones conducidas;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
10p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-1: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. APARATOS DE MEDIDA. (CISPR 16-1-1:2006) |
Código de Doc.:
|
UNE-EN 55016-1-1:2008/A1 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus (CISPR 16-1-1:2006); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Appareils de mesure (CISPR 16-1-1:2006) |
Edición:
|
primera |
Notas:
|
Esta primera modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-1:2007/A1:2007, que a su vez adopta las normas internacionales CISPR 16-1-1:2006/A1:2006 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Receptores;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
7p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-1: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. APARATOS DE MEDIDA. (CISPR 16-1-1:2006) |
Código de Doc.:
|
UNE-EN 55016-1-1 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica las caracteristicas y funcionamiento de los equipos de medida de las tensiones, corrientes y campos radioelectricos perturbadores en el rango de frecuencia de 9 kGz |
Relac. con otras Normas:
|
IEC 60050-151; CISPR 11; CISPR 16-3 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus (CISPR 16-1-1:2006); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-1: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Appareils de mesure (CISPR 16-1-1:2006) |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-1:2007, que a su vez adopta las normas internacionales CISPR 16-1-1:2006 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Receptores;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
74p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION DE LOS METODOS Y APARATOS DE MEDIDA DE LA INMUNIDAD Y DE LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-2: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD. MEDIDA DE LA POTENCIA PERTURBADORA. (CISPR 16-2-2:2003) |
Código de Doc.:
|
UNE-EN 55016-2-2 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica los métodos de medida de fenómenos perturbadores utilizando la pinza de absorción en el rango de frecuencias de 30kHz hasta 1000 Ghz |
Relac. con otras Normas:
|
CISPR 13; CISPR 16-1-1; CISPR 16-1-3, CISPR 16-2-1; CISPR 16-2-3;CISPR 16-2-4; CISPR 16-3; CISPR 16-4-1; CISPR 16-4-2; CISPR 16-4-3 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power (CISPR 16-2-2:2003).; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-2: Méthodes de mesure des perturbations et de l'immunité - Mesure de la puissance perturbatrice (CISPR 16-2-2:2003) |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-2:2004, que a su vez adopta las normas internacionales CISPR 16-2-2:2003 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Potencia perturbadora;
Inmudidad;
Compatibilidad electromagnética;
Pinza de absorción
|
Páginas:
|
34p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACIONES DE LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE INMUNIDAD. PARTE 2-1: METODOS DE MEDIDA DE PERTURBACIONES Y DE LA INMUNIDAD. MEDIDAS DE LA PERTURBACION CONDUCIDA. (CISPR 16-2-1:2003) |
Código de Doc.:
|
UNE-EN 55016-2-1 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica los métodos de medida de fenómenos perturbadores en general en el rango de frecuencias de 9 kHz hasta 18 Ghz y especialmente de fenómenos perturbadores condicodos en el rango hasta 30 MHz |
Relac. con otras Normas:
|
IEC 600083; IEC 600364-4; CISPR 11; CISPR 13; CISPR 16-1-1; CISPR 16-1-2, CISPR 16-2-2; CISPR 16-2-3;CISPR 16-2-4; CISPR 16-3; CISPR 16-4-1; CISPR 16-4-2; CISPR 16-4-3; CISPR 16-4-4 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements (CISPR 16-2-1:2003); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-1: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations conduites (CISPR 16-2-1:2003) |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-1:2004, que a su vez adopta las normas internacionales CISPR 16-2-1:2003 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Perturbaciones conducidas;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
65p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-5: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. EMPLAZAMIENTOS DE ENSAYO PARA CALIBRACION DE ANTENAS DE 30 MHZ A 1000 MHZ |
Código de Doc.:
|
UNE-EN 55016-1-5 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica los requisitos de los emplazamientos de ensayos para calibración, utilizados para llevar a cabo las calibraciones de antenas, así como tambien las caracteristicas de las antenas de ensayo, el procedimiento de emplazamiento de calibración y el criterio de conformidad de emplazamiento |
Relac. con otras Normas:
|
CISPR 16-14-1; CISPR 16-1-1; CISPR 16-3, CISPR 16-4-1; CISPR 16-4-2; CEI 60050-161 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration test sites for 30 MHz to 1 000 MHz; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-5: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Emplacements d'essai pour l'étalonnage des antennes de 30 MHz à 1 000 MHz |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-5:2004, que a su vez adopta las normas internacionales CISPR 16-1-5:2003 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Antenas;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
54p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS PARTE 1-2: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS EQUIPO(S) AUXILIAR(ES) PERTURBACIONES CONDUCIDAS (CISPR 16-1-2:2003) |
Código de Doc.:
|
UNE-EN 55016-1-2:2007 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica las características y funcionamiento ede los equipos de medida de las tensiones y corrientes radio electrícos perturbadores en el rango de frecuencias de 9 kHm 1 GHz |
Relac. con otras Normas:
|
CISPR 16-14-1; CISPR 16-1-1; CISPR 16-2-1, CISPR 16-3, cispr 16-4-1; CISPR 16-4-2; CEI 60050-161 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances (CISPR 16-1-2:2003); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-2: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Perturbations conduites (CISPR 16-1-2:2003) |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-2:2004, que a su vez adopta las normas internacionales CISPR 16-1-2:2004 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Especificaciones;
Perturbaciones radioeléctricas;
Perturbaciones conducidas;
Inmudidad;
Compatibilidad electromagnética
|
Páginas:
|
65p. |
Ingreso de la Info.:
|
2009-01-27 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-2: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. MEDIDA DE LA POTENCIA PERTURBADA (CISPR 16-2-2:2003/A2:2005) |
Código de Doc.:
|
UNE-EN 55016-2-2:2007/A2:2008 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power (CISPR 16-2-2:2003/A2:2005); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-2: Méthodes de mesure des perturbations et de l'immunité - Mesure de la puissance perturbatrice (CISPR 16-2-2:2003/A2:2005) |
Edición:
|
primera |
Notas:
|
Esta segunda modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-2:2004/A2:2005, que a su vez adopta la norma internacional CISPR 16-2-2:2003/A2:2005 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Pertubaciones radiadas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética
|
Páginas:
|
10p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION DE LOS METODOS Y APARATOS DE MEDIDA DE LA INMUNIDAD Y DE LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-3: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD. MEDIDAS DE LAS PERTURBACIONES RADIADAS. (CISPR 16-2-3:2003) |
Código de Doc.:
|
UNE-EN 55016-2-3:2007/A1:2008 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements (CISPR 16-2-3:2003/A1:2005); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-3: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations rayonnées (CISPR 16-2-3:2003/A1:2005) |
Edición:
|
primera |
Notas:
|
Esta primera modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-3:2004/A1:2005, que a su vez adopta la norma internacional CISPR 16-2-3:2003/A1:2005 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Pertubaciones radiadas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética
|
Páginas:
|
12p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-3: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. MEDIDAS DE LAS PERTURBACIONES RADIADAS. (CISPR 16-2-3:2003/A2:2005) |
Código de Doc.:
|
UNE-EN 55016-2-3:2007/A2:2008 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements (CISPR 16-2-3:2003/A2:2005); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-3: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations rayonnées (CISPR 16-2-3:2003/A2:2005) |
Edición:
|
primera |
Notas:
|
Esta segunda modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-3:2004/A2:2005, que a su vez adopta la norma internacional CISPR 16-2-3:2003/A2:2005 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Pertubaciones radiadas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética
|
Páginas:
|
10p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS PARTE 1-2: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. EQUIPO(S) AUXILIAR(ES). PERTURBACIONES CONDUCIDAS |
Código de Doc.:
|
UNE-EN 55016-1-2:2007/A1:2008 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-2: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Perturbations conduites |
Edición:
|
primera |
Notas:
|
Esta primera modificación es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-2:2004/A1:2005, que a su vez adopta la norma internacional CISPR 16-1-2:2003/A1:2004 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Pertubaciones conducidas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética
|
Páginas:
|
16p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACIONES DE LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 4-2: INCERTIDUMBRES, ESTADISTICAS Y MODELIZACION DE LIMITES. INCERTIDUMBRE EN LAS MEDIDAS DE CEM (CISPR 16-4-2:2003) |
Código de Doc.:
|
UNE-EN 55016-4-2 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica la manera en que se han de tener en cuenta las incertidumbres de medida durante la determinación de la conformidad con los límites de CISPR |
Campo de Aplic.:
|
Se aplica igualmente a todos los ensayos CEM cuando las interpretaciones de los resultados y las conclusiones estarán influenciados por la incertidumbre de la instrumentación utilizada durante los ensayos |
Relac. con otras Normas:
|
CISPR 16-1; CISPR 16-2; CISPR 16-3; CISPR 16-4-1; CISPR 16-4-3; CISPR 16-4-4 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 4-2: Uncertainties, statistics and limit modelling - Uncertainty in EMC measurements (CISPR 16-4-2:2003); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 4-2: Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure CEM (CISPR 16-4-2:2003) |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-4-2:2004, que a su vez adopta la norma internacional CISPR 16-4-2:2003 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética;
Incertidumbre
|
Páginas:
|
28p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION DE LOS METODOS Y APARATOS DE MEDIDA DE LA INMUNIDAD Y DE LAS PERTURBACIONES RADIOELECTRICAS. PARTE 2-4: METODOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD. MEDIDA DE LA INMUNIDAD. (CISPR 16-2-4:2003) |
Código de Doc.:
|
UNE-EN 55016-2-4 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2007 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica los métodos de medida de los fenómenos de compatibilidad electromagnética en el rango de frecuencias desde 9 kHz hasta 18 kHz |
Relac. con otras Normas:
|
IEC 60083; IEC 60364-4; CISPR 16-1-3; CISPR 16-1-2 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements (CISPR 16-2-4:2003); Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-4: Méthodes de mesure des perturbations et de l'immunité - Mesures de l'immunité (CISPR 16-2-4:2003) |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-2-4:2004, que a su vez adopta la norma internacional CISPR 16-2-4:2003 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética
|
Páginas:
|
27p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ESPECIFICACION PARA LOS METODOS Y APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. PARTE 1-3: APARATOS DE MEDIDA DE LAS PERTURBACIONES RADIOELECTRICAS Y DE LA INMUNIDAD A LAS PERTURBACIONES RADIOELECTRICAS. EQUIPO(S) AUXILIAR(ES). POTENCIA PERTURBADORA |
Código de Doc.:
|
UNE-EN 55016-1-3 |
Autor Inst.:
|
Asociación Española de Normalización y Certificación. AENOR |
Fecha:
|
2008 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
España |
Objeto:
|
Especifica las características y la calibración de la pinza absorbente para la medida de la potencia perturbadora radioeléctrica en el rango de frecuencias de 30 MHz a 1 GHz |
Relac. con otras Normas:
|
CISPR 16-1-3; CISPR 16-1-2; CISPR 16-1-3/cor.-1; CISPR 16-4-2 |
ICS:
|
33.100.10; 33.100.20 |
Idioma:
|
es |
Título en otro Idioma:
|
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power; Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 1-3: Appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Matériels auxiliaires - Puissance perturbatrice |
Edición:
|
primera |
Notas:
|
Esta norma es la versión oficial, en español, de la Norma Europea EN ISO 55016-1-3:2006, que a su vez adopta las normas internacionales CISPR 16-1-3:2004 y CISPR 16-1-3/cor.-1:2006 |
Palabras Clave: |
Calibración;
Aparatos de medición;
Pinza absorbente;
Especificaciones;
Perturbaciones radioeléctricas;
Inmunidad;
Validación;
Potencia perturbadora;
Compatibilidad electromagnética
|
Páginas:
|
35p. |
Ingreso de la Info.:
|
2009-01-23 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |