Tipo de documento:
|
NORMA |
Título:
|
CONCENTRATOR PHOTOVOLTAIC (CPV) MODULES AND ASSEMBLIES - DESIGN QUALIFICATION AND TYPE APPROVAL |
Código de Doc.:
|
IEC 62108:2007 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2007 |
Estado: |
|
Objeto:
|
Specifies the minimum requirements for the design qualification and type approval of concentrator photovoltaic modules and assemblies suitable for long-term operation in general open-air climates. The test sequence is partially based on that specified in IEC 61215. Determines the electrical, mechanical, and thermal characteristics of the CPV modules and assemblies and shows that the CPV modules and assemblies are capable of withstanding prolonged exposure in climates described in the scope |
ICS:
|
27.160 - Solar energy engineering |
Idioma:
|
en
fr |
Título en otro Idioma:
|
Modules et ensembles photovoltaïques à concentration - Qualification de la conception et homologation |
Edición:
|
1.0 edition |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Concentración
;
Diseño
;
Homologación
|
Páginas:
|
80p. |
Ingreso de la Info.:
|
2016-02-11 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
THIN-FILM TERRESTRIAL PHOTOVOLTAIC (PV) MODULES - DESIGN QUALIFICATION AND TYPE APPROVAL |
Código de Doc.:
|
IEC 61646:2008 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2008 |
Estado: |
|
Objeto:
|
IEC 61646:2008 lays down requirements for the design qualification and type approval of terrestrial, thin-film photovoltaic modules suitable for long-term operation in general open-air climates as defined in IEC 60721-2-1. This standard applies to all terrestrial flat plate module materials not covered by IEC 61215. The significant technical change with respect to the previous edition concerns the pass/fail criteria |
ICS:
|
27.160 - Solar energy engineering |
Idioma:
|
en
fr |
Título en otro Idioma:
|
Modules photovoltaïques (PV) en couches minces pour application terrestre - Qualification de la conception et homologation |
Edición:
|
2.0 edition |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Láminas
;
Diseño
;
Homologación
|
Páginas:
|
81p. |
Ingreso de la Info.:
|
2016-02-11 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
PHOTOVOLTAIC (PV) STAND ALONE SYSTEMS - DESIGN VERIFICATION |
Código de Doc.:
|
IEC 62124:2004 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2004 |
Estado: |
|
Objeto:
|
Verifies system design and performance of stand-alone photovoltaic systems. The performance test consists of a check of the functionality, the autonomy and ability to recover after periods of low state-of-charge of the battery, and hence gives reasonable assurance that the system will not fail prematurely. The testing conditions are intended to represent the majority of climatic zones for which these systems are designed |
ICS:
|
27.160 - Solar energy engineering |
Idioma:
|
en
fr |
Título en otro Idioma:
|
Systèmes photovoltaïques (PV) autonomes - Vérification de la conception |
Edición:
|
1.0 edition |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Equipos
;
Diseño
;
Verificación
|
Páginas:
|
77p. |
Ingreso de la Info.:
|
2016-02-11 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING |
Código de Doc.:
|
IEC 61730-2:2012 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2012 |
Estado: |
|
Objeto:
|
IEC 61730-2:2004+A1:2011 Describes the testing requirements for photovoltaic modules in order to provide safe electrical and mechanical operation during their expected lifetime. Addresses the prevention of electrical shock, fire hazards, and personal injury due to mechanical and environmental stresses. Outlines the requirements of testing and is to be used in conjunction with IEC 61215 or IEC 61646. This consolidated version consists of the first edition (2004) and its amendment 1 (2011). Therefore, no need to order amendment in addition to this publication |
ICS:
|
27.160 - Solar energy engineering |
Título en otro Idioma:
|
Qualification pour la sûreté de fonctionnement des modules photovoltaïques (PV) – Partie 2: Exigences pour les essais |
Edición:
|
1.1b edition |
Notas:
|
Incluye:IEC 61730-2:2004 A1:2011 |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Paneles solares
;
Seguridad eléctrica
;
Ensayos
;
Requisitos
|
Páginas:
|
80p. |
Ingreso de la Info.:
|
2016-02-10 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION |
Código de Doc.:
|
IEC 61730-1:2013 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2013 |
Estado: |
|
Objeto:
|
IEC 61730 1 2004 A1 2011 A2 2013 Describes the fundamental construction requirements for photovoltaic modules in order to provide safe electrical and mechanical operation during their expected lifetime Addresses the prevention of electrical shock fire hazards and personal injury due to mechanical and environmental stresses Pertains to the particular requirements of construction and is to be used in conjunction with IEC 61215 or IEC 61646 b This consolidated version consists of the first edition 2004 its amendment 1 2011 and its amendment 2 2013 Therefore no need to order amendments in addition to this publications |
ICS:
|
27.160 - Solar energy engineering |
Título en otro Idioma:
|
Qualification pour la sûreté de fonctionnement des modules photovoltaïques (PV) – Partie 1: Exigences pour la construction |
Edición:
|
1.2 edition |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Paneles solares
;
Seguridad eléctrica
;
Construcción
|
Ingreso de la Info.:
|
2016-02-10 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
PHOTOVOLTAIC (PV) ARRAY - ON-SITE MEASUREMENT OF CURRENT-VOLTAGE CHARACTERISTICS |
Código de Doc.:
|
IEC 61829:2015 |
Autor Inst.:
|
International Electrotechnical Commission. IEC/CEI |
Fecha:
|
2015 |
Estado: |
|
Objeto:
|
IEC 61829:2015 specifies procedures for on-site measurement of flat-plate photovoltaic (PV) array characteristics, the accompanying meteorological conditions, and use of these for translating to standard test conditions (STC) or other selected conditions. This new edition includes the following significant technical changes with respect to the previous edition;it addresses many outdated procedures;- it accommodates commonly used commercial I-V curve tracers;- it provides a more practical approach for addressing field uncertainties;- it removes and replaces procedures with references to other updated and pertinent standards, including the IEC 60904 series, andIEC 60891 |
ICS:
|
27.160 - Solar energy engineering |
Título en otro Idioma:
|
Champ de modules photovoltaïques (PV) – Mesurage sur site des caractéristiques courant-tension |
Edición:
|
2.0 edition |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Paneles solares
;
Mediciones
;
Dispositivos
;
Corriente eléctrica
;
Voltaje
|
Páginas:
|
34p. |
Ingreso de la Info.:
|
2016-02-10 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ENERGIA SOLAR. MODULOS FOTOVOLTAICOS. PARTE 19: ENSAYO DE EXPOSICION A LA INTEMPERIE |
Código de Doc.:
|
IRAM 210013-19 |
Autor Inst.:
|
Instituto Argentino de Normalización y Certificación. IRAM |
Fecha:
|
2006 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
Argentina |
Objeto:
|
Establece el procedimiento para realizar una evaluación preliminar de la capacidad del módulo fotovoltaico, a resistir a la intemperie y revelar cualquier efecto de degradación |
Relac. con otras Normas:
|
IRAM 210013-1; IRAM 210013-2; IRAM 210013-3; IEC 60721-2-1 |
ICS:
|
27.160.00 Ingeniería de la energía solar |
Otros Códigos:
|
CNA 6117 |
Idioma:
|
es |
Título en otro Idioma:
|
Solar energy. Photovoltaic modules. Part 19: Outdoor exposure test |
Edición:
|
primera edición |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Evaluación
;
Ensayos de resistencia
;
Degradación
|
Páginas:
|
10p. |
Ingreso de la Info.:
|
2010-01-13 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ENERGIA SOLAR. MODULOS FOTOVOLTAICOS. PARTE 18: COMPORTAMIENTO A BAJA IRRADIANCIA |
Código de Doc.:
|
IRAM 210013-18 |
Autor Inst.:
|
Instituto Argentino de Normalización y Certificación. IRAM |
Fecha:
|
2006 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
Argentina |
Objeto:
|
Establece el procedimiento de ensayo para determinar como varía el comportamiento eléctrico del módulo fotovoltaico en función del consumo, a 25grados C y una irradiancia de 200 Wm-2, medido con un dispositivo de referencia apropiado, de acuerdo con los establecido en la IRAM 210013-2 |
Relac. con otras Normas:
|
IRAM 210013-2; IEC 60904-2; IEC 60904-6; ASTM E 927 |
ICS:
|
27.160.00 Ingeniería de la energía solar |
Otros Códigos:
|
CNA 6117 |
Idioma:
|
es |
Título en otro Idioma:
|
Solar energy. Photovoltaic modules. Part 18: Performance at low irradiance |
Edición:
|
primera edición |
Palabras Clave: |
Energía solar
;
Modulos fotovoltaicos
;
Paneles fotovoltaicos
;
Determinación
;
Variación
;
Electricidad
;
Irradiancia espectral
|
Páginas:
|
10p. |
Ingreso de la Info.:
|
2010-01-13 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ENERGIA SOLAR. MODULOS FOTOVOLTAICOS. CALIFICACION DE DISENO Y APROBACION DE TIPO DE MODULOS |
Código de Doc.:
|
IRAM 210013-17 |
Autor Inst.:
|
Instituto Argentino de Normalización y Certificación. IRAM |
Fecha:
|
2003 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
Argentina |
Objeto:
|
Establece los requisitos para la calificación del diseño y la aprobación de tipo de módulos de uso terrestre |
Campo de Aplic.:
|
Aplicable solo a módulos fotovoltaicos de silicio cristalino, solo destinados al uso bajo intemperie |
Relac. con otras Normas:
|
IRAM 18; IRAM 210013-1; IRAM 210013-2; IRAM 210013-3; IRAM 210013-4; IRAM 210013-5; IRAM 210013-6; IRAM 210013-7; IRAM 210013-8; IRAM 210013-9; IRAM 210013-10; IRAM 210013-11; IRAM 210013-14; IRAM 210013-15; IRAM 210013-16; IEC 60904-3 |
ICS:
|
27.160.00 Ingeniería de la energía solar |
Otros Códigos:
|
CNA 6117 |
Idioma:
|
es |
Título en otro Idioma:
|
Solar energy. Photovoltaic modules. Design qualification and type approval of modules |
Edición:
|
primera edición |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Requisitos
;
Diseño
|
Páginas:
|
11p. |
Ingreso de la Info.:
|
2010-01-13 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |
Tipo de documento:
|
NORMA |
Título:
|
ENERGIA SOLAR. MODULOS FOTOVOLTAICOS. PARTE 16: ENSAYO DE TOLERANCIA FRENTE AL EFECTO PUNTO CALIENTE |
Código de Doc.:
|
IRAM 210013-16 |
Autor Inst.:
|
Instituto Argentino de Normalización y Certificación. IRAM |
Fecha:
|
2002 |
Estado: |
Para datos sobre la vigencia de esta norma haga clic aquí |
País de Origen:
|
Argentina |
Objeto:
|
Establece el procedimiento para determinar la capacidad del módulo para soportar los efectos térmicos asociados al fenómeno de punto caliente; por ejemplo ablandamiento de la soldadura, o deterioro del encapsulante. Puede atribuirse a celdas rasjadas, disparidad entre celdas, fallas de interconexión, ensombramientos parciales o suciedad acumulada |
Relac. con otras Normas:
|
ASTM E 927 |
ICS:
|
27.160.00 Ingeniería de la energía solar |
Otros Códigos:
|
CNA 6117 |
Idioma:
|
es |
Título en otro Idioma:
|
Solar energy. Photovoltaic modules. Part 16: Hot - spot endurance test |
Edición:
|
primera edición |
Palabras Clave: |
Energía solar
;
Módulos fotovoltaicos
;
Paneles fotovoltaicos
;
Métodos de determinación
;
Ensayos de resistencia
;
Tolerancia
;
Punto caliente
|
Páginas:
|
13p. |
Ingreso de la Info.:
|
2010-01-13 |
|
Para ver la norma completa busque en la base Normas (solo para personal del INTI) |