Servicios de Información y Documentación

Biblioteca

Término solicitado: SAVARIN, ALEJANDRO/(22)

3 Registro/s encontrado/s en CAT+NORMA



Tipo de Docum.: documento de conferencia
Título: Force standards comparison at 100 KN among national laboratories from Inter American Metrology System SIM
Autor: Villarroel Poblete, Juan Christian; Oliva C., Hernán; Soto Pinto, Luis Rubén; Cárdenas, Alejandro; Torres Guzmán, Jorge C.; Dajes, Arístides; Savarín, Alejandro
Reunión: IMEKO World Congress “Measurement in Research and Industry”, 21, Praga. CZ, 2015
Idioma: eng
Datos de Edición: s.l. AR. s.n. 2015.
Pág./Vol.: 1p.
Descriptores: Sistema Interamericano de Metrología; Metrología; Calibración; Comparadores; Fuerza; Incertidumbre; Mediciones
Resumen: A force comparison was carried out among various laboratories from Inter American System (SIM), in order to estimate the level of agreement for the realization of the quantity and the uncertainty associated to its measurement. The comparison was carried out in the ranges of 50 and 100 kN in compression. In order to achieve best accuracy of the force transducer the measurement range started in 50% of the maximum transducer range. The results obtained, the deviations graphs that include the uncertainty for each laboratory are presented in this document.

Ver Documento

Trabajo de INTI

URL:

https://www.imeko.org/publications/wc-2015/IMEKO-WC-2015-TC3-089.pdf



Tipo de Docum.: artículo
Título: Force key comparison CCM.F-K2.a.1 : 50 kN and 100 kN. Final report
Autor: Savarin, Alejandro; Medina, Nieves; Knott, Andy
Título Ser./Col.: Metrología, 53
Autor Inst. Ser./Col.: Bureau International des Poids et Mesures. BIPM. Paris. FR
Idioma: eng
Datos de Edición: s.l. IOP Publishing. 2016.
Pág./Vol.: 15p.
Descriptores: Metrología; Fuerza; Mediciones; Pesas; Transductores; Instrumentos de medición
Resumen: This report describes CIPM key comparison CCM.F-K2.a.1, a key comparison between force standard machines at the national measurement institutes of Argentina (INTI), Spain (CEM), and the United Kingdom (NPL), at generated forces of 50 kN and 100 kN, in the period from 2010 to 2012. Two transducers were used and the force-time profile was strictly controlled, to minimise effects of creep. The final results are linked to the KCRV determined in CIPM Key Comparison CCM.F-K2.a through the use of one common deadweight force standard machine (NPL's 120 kN machine) in the two comparison exercises.

Ver Documento

Trabajo de INTI

URL:

https://iopscience.iop.org/article/10.1088/0026-1394/53/1A/07001



Tipo de Docum.: documento de conferencia
Título: Mejoras en las capacidades de medición de fuerza del INTI
Autor: Savarín, Alejandro; Fulco, Edgardo; Toyos, Fernando; Alvarez, Pablo; Pérez, Norberto; Malinovsky, Nicolás
Autor Instit.: INTI-Física y Metrología. Buenos Aires. AR
Reunión: Instituto Nacional de Tecnología Industrial. INTI. Buenos Aires. AR, Encuentro de primavera 2011, Encuentro INTI, 10, Buenos Aires. AR, 2011
Idioma: spa
Datos de Edición: Buenos Aires. AR. INTI. 2011.
Pág./Vol.: p.178-179.
Notas: Tema 06: Mayor confiabilidad de productos, P11048.
Unidad técnica: INTI-Física y Metrología.
Descriptores: Fuerza; Mediciones; Equipamiento; Incertidumbre; Calibración

Ver Documento

Trabajo de INTI
  
Ubicación: 4686
Disponibilidad: Consulta in situ



Fin